| S. No | Product | Test Performed | Checking Parameter | Method of Checking | Sample Size | Frequency | IMTE Used | Acceptance Criteria |
| 1. | Pipe Fittings | Physical Verification | Dimensions | Manual | 8 pcs / item | Each Lot | Vernier Calliper | As per SS . QFM / QC / 01 |
| Wall thickness | Manual | 8 pcs / item | -do- | P– type Caliper | As per SS . QFM / QC / 01 |
| Cracks | Visual | 13 pcs / item | -do- | ——– | No cracks as per IS : 1879 – 1987 |
| Unfilled | Visual | -do- | -do- | ——– | No unfilled as per IS : 1879 – 1987 |
| Deep pits | Visual | -do- | -do- | ——– | No deep pits as per IS : 1879 – 1987 |
| Shifting | Visual | -do- | -do- | ——– | No shifting as per IS : 1879 – 1987 |
| Deposits | Visual | -do- | -do- | ——– | No deposits as per IS : 1879 – 1987 |
| Zinc Coatings | Surface smoothness | Visual | -do- | -do- | ———- | Smooth surfaceas as IS : 1879 – 1987 |
| Flux ash | Visual | -do- | -do- | ———- | No flux ash as per IS : 1879 – 1987 |
| Bare patches | Visual | -do- | -do- | ———- | No bare patches as per IS : 1879 -1987 |
| Pimples | Visual | -do- | -do- | ———- | No pimples as per IS : 1879 – 1987 |
| Lumps | Visual | -do- | -do- | ———- | No lumps as per IS : 1879 – 1987 |
| Rust strains | Visual | -do- | -do- | ———- | No rust strains as IS : 1879 – 1987 |
| Excess / less deposits | Visual | -do- | -do- | ———- | No excess/less deposits IS : 1879 – 1987 |
| Alignment Test | Straightness / 90� | Manual | 8 pcs / item | -do- | Jigs | 180�� ��, 90�� �� IS : 1879 – 1987 |
| Chamfering | External / Internal threads | Visual | -do- | -do- | ———- | No item without chamfer |
| Threading | Gauge | | -do- | -do- | Thread Guage | � 1� thread as per IS: 8999 – 1979 |
| Chemical Test | Carbon content | Manual | 2 pcs/item | -do- | | No shifting as per IS : 1879 – 1987 |
| Silicon content | Manual | 2 pcs/item | -do- | | No shifting as per IS : 1879 – 1987 |
| Pneumatic Test | Air–leakage | Manual | Whole Lot | -do- | | At 15 bar pressure no leakage of air bubbles when dipped inside water |
Remarks :- 1. All dimensions are in mm. unless otherwise specified. 2. Calibrated instruments are used for inspection. 3. 100% pneumatic test is performed for gas fittings only. |